Á¦Ç°¸í À¯·®
(GPD,m3/d)
¿°Á¦°ÅÀ²(%) Áö¸§
/±æÀÌ(inch)
Æò°¡Á¶°Ç Á¦Ç°»ç¾ç¼­
RE8040-BLF440 12,650 (47.9) 99.2 8.0 / 40 40" LP High Flux
RE8040-BLF* 11,500 (43.5) 99.2 8.0 / 40 40" LP High Flux
RE8040-BLR440* 11,000 (41.6) 99.6 8.0 / 40 40" LP Standard
RE8040-BLR* 10,000 (37.9) 99.6 8.0 / 40 40" LP Standard
RE8040-BLN440* 13,000 (49.2) 99.5 8.0 / 40 40" LP Standard
RE8040-BLN* 12,000 (45.4) 99.5 8.0 / 40 40" LP Standard
RE4040-BLF* 2,500 (9.5) 99.2 4.0 / 40 40" LP High Flux
RE4040-BLN* 2,600 (9.8) 99.4 4.0 / 40 40" LP Standard
RE4040-BLR* 2,100 (7.9) 99.6 4.0 / 40 40" LP Standard
RE2540-BLR 740 (2.8) 99.4 2.5 / 40 40" LP Standard
RE2540-BLN 930 (3.5) 99.2 2.5 / 40 40" LP Standard
RE2540-BLF 930 (3.5) 99.2 2.5 / 40 40" LP High Flux
RE4021-BLR 1,000 (3.8) 99.4 4.0 / 21 21" LP Condition
RE4021-BLN 1,200 (4.5) 99.2 4.0 / 21 21" LP Standard
RE4021-BLF* 1,200 (4.5) 99.2 4.0 / 21 21" LP High Flux
40" LP High Flux test conditions: NaCl 500 mg/L, Pressure 100 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
40" LP Standard test conditions: NaCl 1,500 mg/L, Pressure 150 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
21" LP High Flux test conditions: NaCl 500 mg/L, Pressure 100 psig, Temperature 25°C, pH 6.5-7.0 Recovery 8%
21" LP Standard test conditions: NaCl 1,500 mg/L, Pressure 150 psig, Temperature 25°C, pH 6.5-7.0 Recovery 8%
21" LP Condition test conditions: NaCl 1,500 mg/L, Pressure 150 psig, Temperature 25°C, pH 6.5-7.0 Recovery 8%
The stated data were obtained after 30 minutes of operation
* These models are tested and certified by NSF to NSF/ANSI/CAN 61.